Neotherm
Vertical, fully automatic thermic fluid heater with four heat-transfer passes — 300 °C at the outlet, 88 % efficiency.

Built for the plant floor
- Three-pass design, economiser not required
- Packaged unit
- Multiple passes on fluid side ensure low pressure drop across the coil, thereby making more head available for process
- High combustion efficiency
- Low heat release rate per unit furnace volume
- Easy conversion to different liquid and gaseous fuels
- Easy access for inspection and cleaning
- High operating efficiency
- Fully automatic unit
- Low system lag and rapid warm up response
- Can attain temperature as high as 300°C at practically no pressure
- Outside the purview of IBR
- Qualified attendant not required
Design
Neotherm is an oil-fired thermic fluid heater of vertical design. It has four heat-transfer passes for optimum efficiency.
Packaged models
Supplied as a packaged unit, so erection takes very little time and site work is minimal. Only power, oil, water and chimney connections are needed to start up.
Fully automatic
Neotherm switches ON and OFF automatically against the temperature set on the temperature controller. A specially trained attendant doesn't need to watch it continuously.
Record efficiency
Efficient combustion, forced circulation, generous heat-transfer areas and a large furnace volume give an overall efficiency of 88 % on NCV of oil.
Applications
Technical specification — Neotherm (oil fired)
| Parameter | NT:50 | NT:100 | NT:200 | NT:300 | NT:400 | NT:600 | NT:800 | NT:1000 | NT:1500 |
|---|---|---|---|---|---|---|---|---|---|
| Capacitykcal/hr | 50,000 | 1,00,000 | 2,00,000 | 3,00,000 | 4,00,000 | 6,00,000 | 8,00,000 | 10,00,000 | 15,00,000 |
| Max operating temperature (outlet)°C | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 | 300 |
| Fuel consumption at full load — LDOkg/hr | 5.4 | 10.8 | 21.5 | 32.4 | 42.9 | 64.3 | 85.7 | 107.2 | 160.8 |
| Fuel consumption at full load — FOkg/hr | – | – | 22.6 | 33.9 | 45 | 67.5 | 90 | 112.5 | 168.7 |
| Efficiency% | 88 | 88 | 88 | 88 | 88 | 88 | 88 | 88 | 88 |
| Burner control | On / Off | On / Off | On / Off | On / Off | On / Off | On / Off | On / Off | On / Off | 2 Stage |
| Electric supply | AC 3 phase 415 V ± 6%, 50 Hz ± 3%, 4 wire system | ||||||||
| Thermic fluid pump motorhp | 3 | 5 | 7.5 | 10 | 10 | 15 | 15 | 20 | 20 |
| Blower motorhp | 1 | 1 | 1.5 | 2 | 3 | 5 | 10 | 10 | 10 |
| Fuel pump motorhp | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 1 | 1 | 1 |
| Fuel oil preheater (FO units)kW | – | – | 4.5 | 6 | 6 | 9 | 12 | 12 | 15 |
| Total electric load — LDO firedhp | 4.5 | 6.5 | 9.5 | 12.5 | 13.5 | 20.5 | 26 | 31 | 41 |
| Total electric load — FO firedhp + kW | – | – | 9.5 + 4.5 | 12.5 + 6 | 13.5 + 6 | 20.5 + 9 | 26 + 12 | 31 + 12 | 41 + 15 |
| Overall dimensions (L × W × H)m | 2 × 2 × 2.5 | 3 × 3 × 2.5 | 4 × 4 × 4 | 4 × 4 × 5 | 4 × 4 × 5 | 4 × 5 × 5 | 4 × 5 × 6 | 4 × 5 × 6 | 6 × 6 × 8 |
| Flue gas outletmm | 200 | 200 | 250 | 250 | 300 | 350 | 500 | 500 | 600 |
| Gross weightkg | 1000 | 1350 | 1750 | 2400 | 2900 | 3500 | 5250 | 5250 | 6500 |
• NCV of LDO: 10,200 kcal/kg · NCV of FO: 9,600 kcal/kg.
• Gas-fired versions available with Riello burners — ask our engineers.
What comes with every unit
The standard supply package, the controls and safeties fitted as standard, and what we need at site, as listed in Neotech's scope of supply.
Standard scope
- Complete Thermic Fluid Heater body with double-jacketed casing and multi-pass coils, having three passes on the flue-gas side so as to provide one radiant and three convective heat transfers.
- Fuel supply system complete with gear pump, pipelines, control valve, oil filter, non-return valve, ignition electrodes, burner assembly and the necessary F.D. fan for supplying combustion air.
- Completely pre-wired control panel with pan-alarm system and centralised indicators for pressure and temperature readings. Necessary controls such as temperature controllers, pressure switches, O/L relays, etc. with internal wiring.
- Centrifugal, air-cooled type Thermic Fluid circulating pump set with TEFC motor.
- Expansion-cum-deaerator tank with inlet / outlet connections, level cock valve and level indicator.
Optional supply
- Oil pre-heating unit to operate the unit on Furnace Oil / LSHS.
Detailed scope sheet — NT-200 & above
| Sr. No. | Description | Qty. | Make / Spec. |
|---|---|---|---|
| MAIN UNIT | 1 Set | Our Design | |
| 1.1 | Thermic Fluid Heater body with a double-jacketed casing as a two-way arrangement, i.e. it also serves as an air pre-heater for better efficiency. An aluminium radiator provided within the heater body ensures cooler surroundings and optimises efficiency. The body carries the top cover, burner block, blower connection and flue-gas outlet, and is finished with three coats of paint to combat corrosive atmospheres. | 1 Set | Our Design |
| 1.2 | Thermic Fluid Heater coil in three-pass design, made from boiler-quality steel tubes, providing 1 radiant and 3 convective heat transfers. (Economiser not required, as 4 heat transfers are achieved within the unit.) | 1 Set | Our Design |
| ANCILLARIES | 1 Set | ||
| 2.1 | Centrifugal-type Thermic Fluid circulating pump with TEFC motor, Love-Joy coupling, coupling guard, etc., mounted on a common base frame with air-cooling arrangement. | 1 Set | Pump: FLOWLINE/EQUIVALENT [air-cooled]. Motor: HMM / EQUIVALENT |
| 2.2 | NEOTECH’S fully-automatic, pressure-jet type, down-firing burner with air swirler, diffuser plate, ignition electrodes, oil spray nozzle, tie rods, sockets, ON-OFF type solenoid valve, sight glass to view the flame, and photocell — complete assembly for flame sensing. | 1 Set | Our own make. Nozzle:- imported. |
| 2.3 | Centrifugal-type combustion air blower driven by a TEFC motor and fitted with an adjustable air regulator. | 1 Set | MS construction with flange-type aluminium air regulator mounted on blower. Impeller dynamically balanced for noise- & vibration-free operation. |
| 2.4 | Rotary-type gear oil pump with inlet, outlet and bypass connections, driven by a separate motor through a Love-Joy coupling. | 1 No. | PRAKASH/ EQUIVALENT |
| 2.5 | Basket-type fuel oil filter (Simplex / Duplex). | 1 No. | “Intervest” make, suitable for LDO and F.O. |
| 2.6 | Fuel oil pressure gauge, mounted on panel. | 1 No. | 0–30 kg/cm², special bakelite-moulded to combat corrosive atmospheres. |
| 2.7 | Fuel oil piping from oil filter to oil pump to burner. | 1 Set | Piping by metallic-braided, high-pressure flexible lines. |
| 2.8 | Non-return valve for fuel oil line. | 1 No. | Zoloto |
| 2.9 | Flanged-end inlet header with thermowell for temperature sensing and isolation valve for pressure lines. The inlet header also carries a pressure-line connection to a pressure switch for Low-Flow / No-Flow safety cut-out. | 1 Set | Made from boiler-quality tubes. |
| 2.10 | Flanged-end outlet header with thermowell for temperature sensing and isolation valve for pressure lines. The outlet header also carries a pressure-line connection to a pressure switch for High-Pressure / No-Flow safety cut-out. | 1 Set | Made from boiler-quality tubes. |
| 2.11 | Completely pre-wired control panel having the following components: (a) Control console box. (b) Contactors and overload protection relays for blower motor and circulation pump motor. (c) Timers for ignition & burner pre-purge. (d) Main switch, programmer switch and other rotary-type selector switches. (e) Part Of Sequence Controller. (f) Return temperature indicator-cum-controller. (g) Outlet temperature indicator-cum-controller. (h) Audio-visual PAN-ALARM system for precise fault indication. (i) Pressure switch for low-pressure cut-out. (j) Pressure switch for high-pressure cut-out. (k) Panel-mounted powder coated pressure gauges. (l) Complete set of nameplates, indicating bulbs, etc. (m) Solid & flexible wires for wiring. (n) Conduit pipes for protection of electrical wires. (o) Ignition transformer. (p) MCB on control circuit to avoid malfunction due to short circuit. | 1 Set | Dust-proof, corrosion-resistant enclosure with rubber sealing. Contactors & timers: Telemecanique. Selector switches: Kaycee. Temp. controllers: digital electronic w/ thermocouple. Pan-alarm: NEOTECH. Pressure switches: INDFOSS. Pressure gauges: 4″ dial, centre connection. Wiring: Finolex / ISI. Conduits: NEC / GEC / equiv. Ignition transformer: Bharat Linder. Fuse units / MCB: MDS / INDO KOPP. |
| 2.12 | Expansion-cum-deaerator tank with inlet / outlet connections, level cock valves, glass tube, etc. | 1 No. | Specially designed, made from MS plates and painted with heat-resistant aluminium paint. |
| 2.13 | Complete set of installation & operation manual and maintenance manual with wiring diagram, P&I diagram, installation diagram, pump foundation drawing and list of items to be arranged at customer’s end. | 1 Set | — |
Battery limits
Fuel Oil
- Inlet of fuel oil filter.
Thermic Fluid
- Suction of Thermic Fluid pump.
- Discharge of Thermic Fluid pump.
- Terminal points of deaerator tank.
- Inlet of Thermic Fluid heater.
- Outlet of Thermic Fluid heater.
Electrical
- Incoming main cable.
- Connection terminals in control panel.
Air & Flue Gas
- Suction of blower.
- Flue gas outlet on heater body.
Standard scope
- Complete Thermic Fluid Heater body with double-jacketed casing and multi-pass coils, having three passes on the flue-gas side so as to provide one radiant and three convective heat transfers.
- Fuel supply system complete with gear pump, pipelines, control valve, oil filter, non-return valve, ignition electrodes, burner assembly and the necessary F.D. fan for supplying combustion air.
- Completely pre-wired control panel with pan-alarm system and centralised indicators for pressure and temperature readings. Necessary controls such as temperature controllers, pressure switches, O/L relays, etc. with internal wiring.
- Centrifugal, air-cooled type Thermic Fluid circulating pump set with TEFC motor.
- Expansion-cum-deaerator tank with inlet / outlet connections, level cock valve and level indicator.
Optional supply
- Oil pre-heating unit to operate the unit on Furnace Oil / LSHS.
Detailed scope sheet — NT-200 & above
| Sr. No. | Description | Qty. | Make / Spec. |
|---|---|---|---|
| MAIN UNIT | 1 Set | Our Design | |
| 1.1 | Thermic Fluid Heater body with a double-jacketed casing as a two-way arrangement, i.e. it also serves as an air pre-heater for better efficiency. An aluminium radiator provided within the heater body ensures cooler surroundings and optimises efficiency. The body carries the top cover, burner block, blower connection and flue-gas outlet, and is finished with three coats of paint to combat corrosive atmospheres. | 1 Set | Our Design |
| 1.2 | Thermic Fluid Heater coil in three-pass design, made from boiler-quality steel tubes, providing 1 radiant and 3 convective heat transfers. (Economiser not required, as 4 heat transfers are achieved within the unit.) | 1 Set | Our Design |
| ANCILLARIES | 1 Set | ||
| 2.1 | Centrifugal-type Thermic Fluid circulating pump with TEFC motor, Love-Joy coupling, coupling guard, etc., mounted on a common base frame with air-cooling arrangement. | 1 Set | Pump: FLOWLINE /EQUIVALENT [air-cooled]. Motor: HMM / NJ / ISI. |
| 2.2 | NEOTECH’S fully-automatic, pressure-jet type, down-firing burner with air swirler, diffuser plate, ignition electrodes, oil spray nozzle, tie rods, sockets, ON-OFF type solenoid valve, sight glass to view the flame, and photocell — complete assembly for flame sensing. | 1 Set | Our own make. Nozzle imported. |
| 2.3 | Centrifugal-type combustion air blower driven by a TEFC motor and fitted with an adjustable air regulator. | 1 Set | MS construction with flange-type aluminium air regulator mounted on blower. Impeller dynamically balanced for noise- & vibration-free operation. |
| 2.4 | Rotary-type gear oil pump with inlet, outlet and bypass connections, driven by a separate motor through a Love-Joy coupling. | 1 No. | PRAKASH/ EQUIVALENT |
| 2.5 | Basket-type fuel oil filter (Simplex / Duplex). | 1 No. | “Intervest” make, suitable for LDO and F.O. |
| 2.6 | Fuel oil pressure gauge, mounted on panel. | 1 No. | 0–30 kg/cm², specially powder coated to combat corrosive atmospheres. |
| 2.7 | Fuel oil piping from oil filter to oil pump to burner. | 1 Set | M.S. Piping with fittings |
| 2.8 | Non-return valve for fuel oil line. | 1 No. | ZOLOTO |
| 2.9 | Flanged-end inlet header with thermowell for temperature sensing and isolation valve for pressure lines. The inlet header also carries a pressure-line connection to a pressure switch for Low-Flow / No-Flow safety cut-out. | 1 Set | Made from boiler-quality tubes. |
| 2.10 | Flanged-end outlet header with thermowell for temperature sensing and isolation valve for pressure lines. The outlet header also carries a pressure-line connection to a pressure switch for High-Pressure / No-Flow safety cut-out. | 1 Set | Made from boiler-quality tubes. |
| 2.11 | Completely pre-wired control panel having the following components: (a) Control console box. (b) Contactors and overload protection relays for blower motor and circulation pump motor. (c) Timers for ignition & burner pre-purge.(part of sequence controller ) (d) Main switch, programmer switch and other rotary-type selector switches. (e) Flame failure unit..(part of sequence controller ) (f) Return temperature indicator-cum-controller. (g) Outlet temperature indicator-cum-controller. (h) Audio-visual PAN-ALARM system for precise fault indication. (i) Pressure switch for low-pressure cut-out. (j) Pressure switch for high-pressure cut-out. (k) Complete set of nameplates, indicating bulbs, etc. (l) Solid & flexible wires for wiring. (m) Conduit pipes for protection of electrical wires. (n) Ignition transformer. (o) Individual fuse units for blower motor, etc. (p) MCB on control circuit to avoid malfunction due to short circuit. | 1 Set | Dust-proof, corrosion-resistant enclosure with rubber sealing. Contactors & timers: Telemecanique. Selector switches: Kaycee. Temp. controllers: digital electronic w/ thermocouple. Pan-alarm: NEOTECH. Pressure switches: INDFOSS. Pressure gauges: 4″ dial, centre connection. Wiring: Finolex / ISI. Conduits: NEC / GEC / equiv. Ignition transformer: Bharat Linder. Fuse units / MCB: MDS / INDO KOPP. |
| 2.12 | Expansion-cum-deaerator tank with inlet / outlet connections, level cock valves, glass tube, etc. | 1 No. | Specially designed, made from MS plates and painted with heat-resistant aluminium paint. |
| 2.13 | Complete set of installation & operation manual and maintenance manual with wiring diagram, P&I diagram, installation diagram, pump foundation drawing and list of items to be arranged at customer’s end. | 1 Set | — |
Battery limits
Fuel Oil
- Inlet of fuel oil filter.
Thermic Fluid
- Suction of Thermic Fluid pump.
- Discharge of Thermic Fluid pump.
- Terminal points of deaerator tank.
- Inlet of Thermic Fluid heater.
- Outlet of Thermic Fluid heater.
Electrical
- Incoming main cable.
- Connection terminals in control panel.
Air & Flue Gas
- Suction of blower.
- Flue gas outlet on heater body.
Get a quotation for Neotherm
Tell us the duty, the fuel available and your location. An engineer will call back with a selection and a price, usually within one working day.
- Office: +91 22 2859 0678
- Factory: +91 98210 28660
- sales@neotechboilers.com
You may also need

Neotherm C
Solid Fuel Fired 3-Pass Thermic Fluid Heater
Coal, wood or briquette fired thermic fluid heater with external furnace and balanced draught — built for low-grade fuels.

Neotherm E
Electrically Heated Thermic Fluid Heater
Skid-mounted electric thermic fluid heating system — 98 % efficient, 280 °C, no chimney, no fuel handling.

Technodry Block
Oil / Gas Fired Hot Air Generator (TDB I & TDB G)
Fully automatic hot air generators delivering clean, uncontaminated hot air for process drying — indirect to 300 °C, direct to 800 °C.