    Home / Products / Thermic Fluid Heaters
    Oil Fired Thermic Fluid Heater

    Neotherm

    Vertical, fully automatic thermic fluid heater with four heat-transfer passes — 300 °C at the outlet, 88 % efficiency.

    50,000 – 15,00,000kcal/hr
    300 °Cmax operating temperature
    88 %efficiency
    LDO / FOfuel
    Models
    NT:50NT:100NT:200NT:300NT:400NT:600NT:800NT:1000NT:1500
    Request a quoteThermic fluid heat load calculatorTechnical data
    Neotherm Oil Fired Thermic Fluid Heater
    Features

    Built for the plant floor

    • Three-pass design, economiser not required
    • Packaged unit
    • Multiple passes on fluid side ensure low pressure drop across the coil, thereby making more head available for process
    • High combustion efficiency
    • Low heat release rate per unit furnace volume
    • Easy conversion to different liquid and gaseous fuels
    • Easy access for inspection and cleaning
    • High operating efficiency
    • Fully automatic unit
    • Low system lag and rapid warm up response
    • Can attain temperature as high as 300°C at practically no pressure
    • Outside the purview of IBR
    • Qualified attendant not required

    Design

    Neotherm is an oil-fired thermic fluid heater of vertical design. It has four heat-transfer passes for optimum efficiency.

    Packaged models

    Supplied as a packaged unit, so erection takes very little time and site work is minimal. Only power, oil, water and chimney connections are needed to start up.

    Fully automatic

    Neotherm switches ON and OFF automatically against the temperature set on the temperature controller. A specially trained attendant doesn't need to watch it continuously.

    Record efficiency

    Efficient combustion, forced circulation, generous heat-transfer areas and a large furnace volume give an overall efficiency of 88 % on NCV of oil.

    Applications

    Chemical reactorsDyeing & stentersCorrugationRubber & tyreEdible oil & foodHot-melt & bitumen

    Technical specification — Neotherm (oil fired)

    ParameterNT:50NT:100NT:200NT:300NT:400NT:600NT:800NT:1000NT:1500
    Capacitykcal/hr50,0001,00,0002,00,0003,00,0004,00,0006,00,0008,00,00010,00,00015,00,000
    Max operating temperature (outlet)°C300300300300300300300300300
    Fuel consumption at full load — LDOkg/hr5.410.821.532.442.964.385.7107.2160.8
    Fuel consumption at full load — FOkg/hr––22.633.94567.590112.5168.7
    Efficiency%888888888888888888
    Burner controlOn / OffOn / OffOn / OffOn / OffOn / OffOn / OffOn / OffOn / Off2 Stage
    Electric supplyAC 3 phase 415 V ± 6%, 50 Hz ± 3%, 4 wire system
    Thermic fluid pump motorhp357.5101015152020
    Blower motorhp111.5235101010
    Fuel pump motorhp0.50.50.50.50.50.5111
    Fuel oil preheater (FO units)kW––4.5669121215
    Total electric load — LDO firedhp4.56.59.512.513.520.5263141
    Total electric load — FO firedhp + kW––9.5 + 4.512.5 + 613.5 + 620.5 + 926 + 1231 + 1241 + 15
    Overall dimensions (L × W × H)m2 × 2 × 2.53 × 3 × 2.54 × 4 × 44 × 4 × 54 × 4 × 54 × 5 × 54 × 5 × 64 × 5 × 66 × 6 × 8
    Flue gas outletmm200200250250300350500500600
    Gross weightkg100013501750240029003500525052506500

    • NCV of LDO: 10,200 kcal/kg · NCV of FO: 9,600 kcal/kg.

    • Gas-fired versions available with Riello burners — ask our engineers.

    Scope of supply

    What comes with every unit

    The standard supply package, the controls and safeties fitted as standard, and what we need at site, as listed in Neotech's scope of supply.

    Standard scope
    • Complete Thermic Fluid Heater body with double-jacketed casing and multi-pass coils, having three passes on the flue-gas side so as to provide one radiant and three convective heat transfers.
    • Fuel supply system complete with gear pump, pipelines, control valve, oil filter, non-return valve, ignition electrodes, burner assembly and the necessary F.D. fan for supplying combustion air.
    • Completely pre-wired control panel with pan-alarm system and centralised indicators for pressure and temperature readings. Necessary controls such as temperature controllers, pressure switches, O/L relays, etc. with internal wiring.
    • Centrifugal, air-cooled type Thermic Fluid circulating pump set with TEFC motor.
    • Expansion-cum-deaerator tank with inlet / outlet connections, level cock valve and level indicator.
    Optional supply
    • Oil pre-heating unit to operate the unit on Furnace Oil / LSHS.
    Detailed scope sheet — NT-200 & above
    Sr. No.DescriptionQty.Make / Spec.
    MAIN UNIT1 SetOur Design
    1.1Thermic Fluid Heater body with a double-jacketed casing as a two-way arrangement, i.e. it also serves as an air pre-heater for better efficiency. An aluminium radiator provided within the heater body ensures cooler surroundings and optimises efficiency. The body carries the top cover, burner block, blower connection and flue-gas outlet, and is finished with three coats of paint to combat corrosive atmospheres.1 SetOur Design
    1.2Thermic Fluid Heater coil in three-pass design, made from boiler-quality steel tubes, providing 1 radiant and 3 convective heat transfers. (Economiser not required, as 4 heat transfers are achieved within the unit.)1 SetOur Design
    ANCILLARIES1 Set
    2.1Centrifugal-type Thermic Fluid circulating pump with TEFC motor, Love-Joy coupling, coupling guard, etc., mounted on a common base frame with air-cooling arrangement.1 SetPump: FLOWLINE/EQUIVALENT [air-cooled]. Motor: HMM / EQUIVALENT
    2.2NEOTECH’S fully-automatic, pressure-jet type, down-firing burner with air swirler, diffuser plate, ignition electrodes, oil spray nozzle, tie rods, sockets, ON-OFF type solenoid valve, sight glass to view the flame, and photocell — complete assembly for flame sensing.1 SetOur own make. Nozzle:- imported.
    2.3Centrifugal-type combustion air blower driven by a TEFC motor and fitted with an adjustable air regulator.1 SetMS construction with flange-type aluminium air regulator mounted on blower. Impeller dynamically balanced for noise- & vibration-free operation.
    2.4Rotary-type gear oil pump with inlet, outlet and bypass connections, driven by a separate motor through a Love-Joy coupling.1 No.PRAKASH/ EQUIVALENT
    2.5Basket-type fuel oil filter (Simplex / Duplex).1 No.“Intervest” make, suitable for LDO and F.O.
    2.6Fuel oil pressure gauge, mounted on panel.1 No.0–30 kg/cm², special bakelite-moulded to combat corrosive atmospheres.
    2.7Fuel oil piping from oil filter to oil pump to burner.1 SetPiping by metallic-braided, high-pressure flexible lines.
    2.8Non-return valve for fuel oil line.1 No.Zoloto
    2.9Flanged-end inlet header with thermowell for temperature sensing and isolation valve for pressure lines. The inlet header also carries a pressure-line connection to a pressure switch for Low-Flow / No-Flow safety cut-out.1 SetMade from boiler-quality tubes.
    2.10Flanged-end outlet header with thermowell for temperature sensing and isolation valve for pressure lines. The outlet header also carries a pressure-line connection to a pressure switch for High-Pressure / No-Flow safety cut-out.1 SetMade from boiler-quality tubes.
    2.11Completely pre-wired control panel having the following components: (a) Control console box. (b) Contactors and overload protection relays for blower motor and circulation pump motor. (c) Timers for ignition & burner pre-purge. (d) Main switch, programmer switch and other rotary-type selector switches. (e) Part Of Sequence Controller. (f) Return temperature indicator-cum-controller. (g) Outlet temperature indicator-cum-controller. (h) Audio-visual PAN-ALARM system for precise fault indication. (i) Pressure switch for low-pressure cut-out. (j) Pressure switch for high-pressure cut-out. (k) Panel-mounted powder coated pressure gauges. (l) Complete set of nameplates, indicating bulbs, etc. (m) Solid & flexible wires for wiring. (n) Conduit pipes for protection of electrical wires. (o) Ignition transformer. (p) MCB on control circuit to avoid malfunction due to short circuit.1 SetDust-proof, corrosion-resistant enclosure with rubber sealing. Contactors & timers: Telemecanique. Selector switches: Kaycee. Temp. controllers: digital electronic w/ thermocouple. Pan-alarm: NEOTECH. Pressure switches: INDFOSS. Pressure gauges: 4″ dial, centre connection. Wiring: Finolex / ISI. Conduits: NEC / GEC / equiv. Ignition transformer: Bharat Linder. Fuse units / MCB: MDS / INDO KOPP.
    2.12Expansion-cum-deaerator tank with inlet / outlet connections, level cock valves, glass tube, etc.1 No.Specially designed, made from MS plates and painted with heat-resistant aluminium paint.
    2.13Complete set of installation & operation manual and maintenance manual with wiring diagram, P&I diagram, installation diagram, pump foundation drawing and list of items to be arranged at customer’s end.1 Set—
    Battery limits
    Fuel Oil
    • Inlet of fuel oil filter.
    Thermic Fluid
    • Suction of Thermic Fluid pump.
    • Discharge of Thermic Fluid pump.
    • Terminal points of deaerator tank.
    • Inlet of Thermic Fluid heater.
    • Outlet of Thermic Fluid heater.
    Electrical
    • Incoming main cable.
    • Connection terminals in control panel.
    Air & Flue Gas
    • Suction of blower.
    • Flue gas outlet on heater body.
    Standard scope
    • Complete Thermic Fluid Heater body with double-jacketed casing and multi-pass coils, having three passes on the flue-gas side so as to provide one radiant and three convective heat transfers.
    • Fuel supply system complete with gear pump, pipelines, control valve, oil filter, non-return valve, ignition electrodes, burner assembly and the necessary F.D. fan for supplying combustion air.
    • Completely pre-wired control panel with pan-alarm system and centralised indicators for pressure and temperature readings. Necessary controls such as temperature controllers, pressure switches, O/L relays, etc. with internal wiring.
    • Centrifugal, air-cooled type Thermic Fluid circulating pump set with TEFC motor.
    • Expansion-cum-deaerator tank with inlet / outlet connections, level cock valve and level indicator.
    Optional supply
    • Oil pre-heating unit to operate the unit on Furnace Oil / LSHS.
    Detailed scope sheet — NT-200 & above
    Sr. No.DescriptionQty.Make / Spec.
    MAIN UNIT1 SetOur Design
    1.1Thermic Fluid Heater body with a double-jacketed casing as a two-way arrangement, i.e. it also serves as an air pre-heater for better efficiency. An aluminium radiator provided within the heater body ensures cooler surroundings and optimises efficiency. The body carries the top cover, burner block, blower connection and flue-gas outlet, and is finished with three coats of paint to combat corrosive atmospheres.1 SetOur Design
    1.2Thermic Fluid Heater coil in three-pass design, made from boiler-quality steel tubes, providing 1 radiant and 3 convective heat transfers. (Economiser not required, as 4 heat transfers are achieved within the unit.)1 SetOur Design
    ANCILLARIES1 Set
    2.1Centrifugal-type Thermic Fluid circulating pump with TEFC motor, Love-Joy coupling, coupling guard, etc., mounted on a common base frame with air-cooling arrangement.1 SetPump: FLOWLINE /EQUIVALENT [air-cooled]. Motor: HMM / NJ / ISI.
    2.2NEOTECH’S fully-automatic, pressure-jet type, down-firing burner with air swirler, diffuser plate, ignition electrodes, oil spray nozzle, tie rods, sockets, ON-OFF type solenoid valve, sight glass to view the flame, and photocell — complete assembly for flame sensing.1 SetOur own make. Nozzle imported.
    2.3Centrifugal-type combustion air blower driven by a TEFC motor and fitted with an adjustable air regulator.1 SetMS construction with flange-type aluminium air regulator mounted on blower. Impeller dynamically balanced for noise- & vibration-free operation.
    2.4Rotary-type gear oil pump with inlet, outlet and bypass connections, driven by a separate motor through a Love-Joy coupling.1 No.PRAKASH/ EQUIVALENT
    2.5Basket-type fuel oil filter (Simplex / Duplex).1 No.“Intervest” make, suitable for LDO and F.O.
    2.6Fuel oil pressure gauge, mounted on panel.1 No.0–30 kg/cm², specially powder coated to combat corrosive atmospheres.
    2.7Fuel oil piping from oil filter to oil pump to burner.1 SetM.S. Piping with fittings
    2.8Non-return valve for fuel oil line.1 No.ZOLOTO
    2.9Flanged-end inlet header with thermowell for temperature sensing and isolation valve for pressure lines. The inlet header also carries a pressure-line connection to a pressure switch for Low-Flow / No-Flow safety cut-out.1 SetMade from boiler-quality tubes.
    2.10Flanged-end outlet header with thermowell for temperature sensing and isolation valve for pressure lines. The outlet header also carries a pressure-line connection to a pressure switch for High-Pressure / No-Flow safety cut-out.1 SetMade from boiler-quality tubes.
    2.11Completely pre-wired control panel having the following components: (a) Control console box. (b) Contactors and overload protection relays for blower motor and circulation pump motor. (c) Timers for ignition & burner pre-purge.(part of sequence controller ) (d) Main switch, programmer switch and other rotary-type selector switches. (e) Flame failure unit..(part of sequence controller ) (f) Return temperature indicator-cum-controller. (g) Outlet temperature indicator-cum-controller. (h) Audio-visual PAN-ALARM system for precise fault indication. (i) Pressure switch for low-pressure cut-out. (j) Pressure switch for high-pressure cut-out. (k) Complete set of nameplates, indicating bulbs, etc. (l) Solid & flexible wires for wiring. (m) Conduit pipes for protection of electrical wires. (n) Ignition transformer. (o) Individual fuse units for blower motor, etc. (p) MCB on control circuit to avoid malfunction due to short circuit.1 SetDust-proof, corrosion-resistant enclosure with rubber sealing. Contactors & timers: Telemecanique. Selector switches: Kaycee. Temp. controllers: digital electronic w/ thermocouple. Pan-alarm: NEOTECH. Pressure switches: INDFOSS. Pressure gauges: 4″ dial, centre connection. Wiring: Finolex / ISI. Conduits: NEC / GEC / equiv. Ignition transformer: Bharat Linder. Fuse units / MCB: MDS / INDO KOPP.
    2.12Expansion-cum-deaerator tank with inlet / outlet connections, level cock valves, glass tube, etc.1 No.Specially designed, made from MS plates and painted with heat-resistant aluminium paint.
    2.13Complete set of installation & operation manual and maintenance manual with wiring diagram, P&I diagram, installation diagram, pump foundation drawing and list of items to be arranged at customer’s end.1 Set—
    Battery limits
    Fuel Oil
    • Inlet of fuel oil filter.
    Thermic Fluid
    • Suction of Thermic Fluid pump.
    • Discharge of Thermic Fluid pump.
    • Terminal points of deaerator tank.
    • Inlet of Thermic Fluid heater.
    • Outlet of Thermic Fluid heater.
    Electrical
    • Incoming main cable.
    • Connection terminals in control panel.
    Air & Flue Gas
    • Suction of blower.
    • Flue gas outlet on heater body.
    Enquiry

    Get a quotation for Neotherm

    Tell us the duty, the fuel available and your location. An engineer will call back with a selection and a price, usually within one working day.

    • Office: +91 22 2859 0678
    • Factory: +91 98210 28660
    • sales@neotechboilers.com

    Related

    You may also need

    Neotherm C — Solid Fuel Fired 3-Pass Thermic Fluid Heater
    Solid fuel

    Neotherm C

    Solid Fuel Fired 3-Pass Thermic Fluid Heater
    Coal, wood or briquette fired thermic fluid heater with external furnace and balanced draught — built for low-grade fuels.

    1,00,000 – 10,00,000kcal/hr
    300 °Coutlet temperature
    Neotherm E — Electrically Heated Thermic Fluid Heater
    Electric

    Neotherm E

    Electrically Heated Thermic Fluid Heater
    Skid-mounted electric thermic fluid heating system — 98 % efficient, 280 °C, no chimney, no fuel handling.

    10,000 – 70,000kcal/hr
    280 °Cmax operating temperature
    Technodry Block — Oil / Gas Fired Hot Air Generator (TDB I & TDB G)
    OilGas

    Technodry Block

    Oil / Gas Fired Hot Air Generator (TDB I & TDB G)
    Fully automatic hot air generators delivering clean, uncontaminated hot air for process drying — indirect to 300 °C, direct to 800 °C.

    30,000 – 10,00,000kcal/hr range
    150 °C stdup to 400 °C models
    Neotech Energy Systems Pvt. Ltd.

    End to end heating solutions since 1991. Non-IBR steam boilers, thermic fluid heaters, hot air and hot water generators and industrial heat pumps, designed and built in our own factories at Asangaon.

    ISO 9001:2015Riello authorisedMade in India
    Follow Neotech
    Instagram ↗ Facebook ↗ Google reviews ↗
    Products
    • Steam boilers
    • Thermic fluid heaters
    • Hot air generators
    • Hot water generators
    • Industrial heat pumps
    • Gas piping
    • Burner conversions & spares
    • Process equipment
    • All products →
    Company
    • Sizing calculators
    • Director's Desk
    • Blog
    • Contact us
    • Sunniva Heat Pumps ↗
    Contact
    Office & service centre213, East West Industrial Centre, Safed Pool, Andheri-Kurla Road, Andheri (E), Mumbai 400 072
    +91 22 2859 0678 · +91 22 2859 9235
    FactoryShed No. 15/16/17, Rukma Industrial Estate, Mumbai–Nashik Highway, Village Asangaon, Tal. Shahpur, Dist. Thane 421 601
    +91 98210 28660 · +91 98210 99894
    sales@neotechboilers.com