Skip to Content
Home / Products / Steam Boilers & Generators
Oil Fired Steam Boiler

Revotech

Non-IBR, four-pass, fully automatic coil-type steam boiler with the Reverse Flue combustion principle.

300 – 1000kg/hr steam (F&A 100 °C)
15 kg/cm²working pressure
88 ± 2 %efficiency on NCV
LDO / FO / HSDfuel
Revotech Oil Fired Steam Boiler
Features

Built for the plant floor

  • Four-pass design with economizer
  • Reverse flue design
  • Packaged unit
  • High combustion efficiency
  • Easy conversion to different liquid and gaseous fuels
  • Easy access for inspection and cleaning
  • High operating efficiency
  • Fully automatic unit
  • Low system lag and rapid warm up response
  • Insulated boiler body to minimize radiation losses
  • Outside the purview of IBR
  • Can attain pressure upto 15kg/cm²
  • Fail-safe design, dependable safety instruments
  • Instant steaming
  • Explosion possibilities are nil
  • Qualified attendant not required

Operating principle

Revotech is the latest design in coil-type non-IBR boilers. It uses a revolutionary combustion principle known as Reverse Flue, which increases combustion efficiency and allows a high rate of heat flux, in a four-pass design. Preheated air is used to establish combustion. Two passes are completed in the radiant zone within the coil; the third pass, between coil and shell, is convective; the fourth runs through an Efficiency Module — an atmospheric economiser that preheats incoming feed water. A heat optimiser keeps the feed water at the correct temperature for the pump.

Non-IBR

The volumetric holding of the steam-generating coil is less than 25 litres, so the boiler is exempted from the Indian Boiler Regulations (IBR).

Packaged, unitised design

Supplied as a packaged unit — main boiler with atmospheric economiser, fully automatic combustion system, boiler feed pump and control panel on one base frame. Erection time is minimal: only water, power, steam and chimney connections are needed.

Fully automatic, instant steaming

Revotech switches ON and OFF automatically against the steam pressure set on the pressure switch, so it doesn't need a specially trained attendant watching it continuously. Forced circulation, water-tube construction and the reverse-flue design bring the boiler to full working pressure within 3 to 5 minutes from cold.

Record efficiency

The reverse-flue design, efficiency module, integral air preheater and economiser together give an overall thermal efficiency of 88 % on NCV of oil.

Applications

Dyes & chemicalsPharmaceuticalsCorrugation & packagingRubberTextilesLaundriesFood processing

Technical specification — Revotech (oil fired)

ParameterRT-03RT-04RT-05RT-06RT-08RT-085RT-10
Steam output (F&A 100 °C)kg/hr3004005006008008501000
Steam pressurekg/cm²15151515151515
Fuel consumption — LDOkg/hr18243036485160
Fuel consumption — FOkg/hr19.125.431.838.150.85463.6
Efficiency (NCV)%88 ± 288 ± 288 ± 288 ± 288 ± 288 ± 288 ± 2
Start-upminutes3355555
Burner controlOn / Off
Pressure partsOutside the purview of IBR
Electric supplyAC 3 phase 415 V ± 6%, 50 Hz ± 3%, 4 wire system
Feed water pump motorhp11111.51.51.5
Blower motorhp111.51.5335
Fuel pump motorhp0.50.50.50.50.50.50.5
Fuel oil preheater (FO units only)kW34.5667.57.57.5
Total electric load — LDO fired2.5 hp2.5 hp3 hp3 hp5 hp5 hp7 hp
Total electric load — FO fired2.5 hp + 3 kW2.5 hp + 4.5 kW3 hp + 6 kW3 hp + 6 kW5 hp + 7.5 kW5 hp + 7.5 kW7 hp + 7.5 kW
Flue gas outletmm200200200250300300300
Dry weightkg1300140016001700180019001950

• NCV of HSD: 10,400 kcal/kg · NCV of LDO: 10,200 kcal/kg · NCV of FO: 9,600 kcal/kg.

• Designs and specifications are subject to change due to constant research & development.

Scope of supply

What comes with every unit

The standard supply package, the controls and safeties fitted as standard, and what we need at site, as listed in Neotech's scope of supply.

Boiler: standard scope
  • Pressure part assembly: closely wound helical vertical coil fabricated from boiler quality pipes, with specially designed spacers.
  • Down-firing, pressure jet burner assembly.
  • Double-jacketed air casing enclosing the pressure parts, serving as an integral combustion air pre-heater with specially designed aluminium radiator to minimise radiation losses and maximise efficiency.
  • Specially designed shell & tube type atmospheric economiser at the flue gas outlet to preserve heat and optimise boiler efficiency.
Accessories
  • Centrifugal blower with motor, mounted on a special frame.
  • Fuel pump coupled with motor, mounted on a special frame with guard.
  • Boiler feed pump with surge suppressor and relief valve, motor-driven, mounted on the same frame.
  • Dust-proof, pre-wired control panel housing starters, MCBs, contactors, relays, and associated components.
Piping
  • Feed water line between economiser, optimiser, feed pump, and boiler.
  • Fuel oil line from filter to burner inlet.
  • Steam header with feed check valve.
Mountings & fittings
  • Main steam stop valve.
  • Auxiliary steam bypass valve.
  • Single-port spring-loaded safety valve.
  • Blow-down valve.
  • Drain valve for economiser.
  • Non-return valve on feed water line.
  • Solenoid valve on fuel oil inlet to burner.
  • Three isolating needle valves for indicating instruments.
  • Simplex oil filter.
  • Simplex water filter.
Instruments, controls & safeties
  • Steam pressure indicator.
  • Digital electronic steam temperature indicator-cum-controller.
  • Steam pressure switch for ON/OFF combustion control.
  • Fuel oil pressure indicator.
  • Feed water temperature indicator.
  • Feed water pressure indicator.
  • Low-level control.
  • Flame failure device (part of sequence controller).
  • Audio-visual alarm for abnormal conditions.
  • Limit switch on blow-down line.
  • Explosion door.
Battery limits
Steam
  • Main steam stop valve
  • Auxiliary steam bypass valve
  • Safety valve on steam outlet line
Water
  • Inlet of heat optimiser
  • Blow-down valve outlet
  • Drain connection for water pump relief valve
  • Air vent connection for economiser
Fuel Oil
  • Inlet of fuel oil filter
Air & Flue Gas
  • Suction of blower
  • Flue gas outlet on economiser
Electricals
  • Terminal connectors on control panel

Site requirements

Performance criteria
Fuel — Light Diesel Oil (LDO) / High Speed Diesel (HSD)
Filtration120 Mesh — free of water and sediment
Net Calorific Value (NCV)10,200 Kcal/kg
Viscosity @ 37.8°CAs per IS specification
Fuel — Furnace Oil (FO)
Viscosity (max)390 cSt @ 50°C
Net Calorific Value (NCV)11.24 kWh/kg
Density @ 15°C0.91 kg/Litre
ConditionFree of water & sediment — filtered through 150 mesh
Feed Water Quality
Hardness< 5 ppm
Dissolved O₂Nil
pH Value8.5 – 9.5
Free CO₂Nil
Bound CO₂< 5 ppm
TDS400 ppm max.
Temperature30°C max.
ConditionFiltered, free from sediment and turbidity
Electrical Power Supply
Voltage415 V ± 6%
Frequency50 Hz ± 3%
PhasesThree-phase + Neutral
EarthingYes — double earthing required
Enquiry

Get a quotation for Revotech

Tell us the duty, the fuel available and your location. An engineer will call back with a selection and a price, usually within one working day.