Nanomatic
Extremely compact, portable steam generators for small, regular requirements of dry steam — electric, gas or oil fired.

Built for the plant floor
- Extremely compact & portable models
- Imported 'RIELLO' burner, with reliable components
- Low power requirement
- Low operating cost
- User friendly
- Minimal maintenance
- Qualified operator not required
- Shell & tube design
- High combustion efficiency
- Low heat release rate per unit furnace volume
- Easy conversion to different liquid and gaseous fuels
- Easy access for inspection and cleaning
- Fully automatic unit
- Low system lag and rapid warm up response
- Outside the purview of IBR
- High efficiency
Oil and gas fired
Neotech's Nanomatic oil and gas steam generators come in four sizes: 35, 50, 100 and 150 kg/hr. They have a compact design and imported world-class monoblock burners, and work at close to 90 % efficiency. They are extremely easy to install and operate, need minimal maintenance, and suit small requirements for dry steam at regular intervals.
Electrically heated — NM 'E'
The electrically heated Nanomatic is offered from 10 to 190 kg/hr. Where it is needed, a version with a higher working pressure (up to 6 kg/cm²) is available on demand.
Applications
Technical specification — Nanomatic
Electrically heated — NM 'E'
| Model | Steam O/P kg/hr | Pressure kg/cm² | Heating load kW | Water pump hp |
|---|---|---|---|---|
| NME-10 | 10 | 4 | 6 | 1 |
| NME-14 | 14 | 4 | 8 | 1 |
| NME-20 | 20 | 4 | 12 | 1 |
| NME-30 | 30 | 4 | 18 | 1 |
| NME-40 | 40 | 4 | 27 | 1 |
| NME-50 | 50 | 4 | 33 | 1 |
| NME-60 | 60 | 4 | 39 | 1 |
| NME-70 | 70 | 4 | 45 | 1 |
| NME-80 | 80 | 4 | 54 | 1 |
| NME-100 | 100 | 4 | 70 | 1 |
| NME-120 | 120 | 4 | 85 | 1 |
| NME-140 | 140 | 4 | 93 | 1 |
| NME-190 | 190 | 4 | 135 | 1 |
Gas fired — NM 'G'
| Model | Steam O/P kg/hr | Pressure kg/cm² | NG m³/hr | LPG kg/hr | Burner load hp | Water pump hp |
|---|---|---|---|---|---|---|
| NM'G'-35 | 35 | 4 | 2.5 | 2 | 0.2 | 1 |
| NM'G'-50 | 50 | 4 | 3.5 | 2.6 | 0.2 | 1 |
| NM'G'-100 | 100 | 4 | 7 | 5.2 | 0.2 | 1 |
| NM'G'-150 | 150 | 4 | 10.5 | 7.8 | 0.2 | 1 |
Oil fired — NM 'O'
| Model | Steam O/P kg/hr | Pressure kg/cm² | Fuel (full load) L/hr | Burner load hp | Water pump hp |
|---|---|---|---|---|---|
| NM'O'-35 | 35 | 4 | 2.75 | 0.2 | 1 |
| NM'O'-50 | 50 | 4 | 3.6 | 0.2 | 1 |
| NM'O'-100 | 100 | 4 | 7.2 | 0.2 | 1 |
| NM'O'-150 | 150 | 4 | 10.8 | 0.2 | 1 |
• Electric supply: AC 3 phase 415 V ± 6%, 50 Hz ± 3%, 4 wire system. Single-phase option available for gas and oil fired models.
• Higher working pressure (up to 6 kg/cm²) available on demand.
What comes with every unit
The standard supply package, the controls and safeties fitted as standard, and what we need at site, as listed in Neotech's scope of supply.
Standard scope
- Complete Steam Generator in shell & tube design and having multiple passes on flue gas side for better heat transfer.
- One burner assembly of monoblock design and suitable for LPG/NG firing. The Burner will be supplied with total controls for fully automatic operation and safeties for totally safe operation, along with gas train.
- Completely pre-wired Control Panel with pan-alarm system centralised, indicators for pressure and temperature readings.
- Necessary controls like temperature controllers, pressure switches, overload relays, etc. with internal wiring.
- Internal piping mounting & fittings like outlet valves, safety valve, inlet valves, drain valve, etc.
Battery limits
Fuel
- Inlet of Gas Burner.
Water
- Suction of water pump.
Steam
- Outlet of Steam Generator.
Electrical
- Terminal connections in control panel.
Air & Flue Gas
- Suction of blower.
- Flue gas outlet on heater body.
Standard scope
- Complete Steam Generator in shell & tube design and having multiple passes on flue gas side for better heat transfer.
- One burner assembly of monoblock design and suitable for diesel firing. The Burner will be supplied with total controls for fully automatic operation and safeties for totally safe operation.
- Complete pre-wired Control Panel with pan-alarm system centralised, indicators for pressure and temperature readings. Necessary controls like temperature controllers, pressure switches, overload relays, etc. with internal wiring.
- Centrifugal type Air cooled Pump set with TEFC motor with internal piping mounting & fittings like outlet valves, safety valve, inlet valves, drain valve, etc.
Battery limits
Water
- Suction of water pump.
Steam
- Outlet of Steam Generator.
Electrical
- Terminal connections in control panel.
Air & Flue Gas
- Suction of blower.
- Flue gas outlet on heater body.
Site requirements
Performance criteria
Fuel — Light Diesel Oil (LDO) / High Speed Diesel (HSD)
| Filtration | 120 Mesh — free of water and sediment |
|---|---|
| Net Calorific Value (NCV) | 10,200 Kcal/kg |
| Viscosity @ 37.8°C | As per IS specification |
Feed Water Quality
| Hardness | < 5 ppm |
|---|---|
| Dissolved O₂ | Nil |
| pH Value | 8.5 – 9.5 |
| Free CO₂ | Nil |
| Bound CO₂ | < 5 ppm |
| TDS | 400 ppm max. |
| Temperature | 30°C max. |
| Condition | Filtered, free from sediment and turbidity |
Electrical Power Supply
| Voltage | 415 V ± 6% |
|---|---|
| Frequency | 50 Hz ± 3% |
| Phases | Three-phase + Neutral |
| Earthing | Yes — double earthing required |
Standard scope
- Complete Steam Generator Made from M.S. Plates of heavy duty steel materials, with matching mounting arrangement for electrical heaters, provisions for requisite mounting & fittings.
- The steam generator will be fitted in a powder coated sheet metal casing for safety & aesthetics.
- One Set of Electrical Heaters made from S.S. Tubes & Swaged quality for better life.
- One of Monoblock pump for water feeding.
- Complete pre-wired Control Panel with pan-alarm system centralized, indicators for pressure and temperature readings.
- Necessary controls like temperature controllers, pressure switches, overload relays, etc. with internal wiring.
- Internal piping mounting & fittings like outlet valves, safety valve, inlet valves, drain valve etc.
Battery limits
Water
- Suction of water pump.
Steam
- Outlet of Steam Generator.
Electrical
- Terminal connections in control panel.
Site requirements
Performance criteria
| Sr. No. | Parameter | Details |
|---|---|---|
| 1 | Feed Water | Filtered, free from sediment and turbidity, clear water |
| 2 | Hardness | < 5 ppm |
| 3 | O2 Content | Nil |
| 4 | PH Value | 8.5 – 9.5 |
| 5 | Free CO2 | Nil |
| 6 | Bound CO2 | < 5 ppm |
| 7 | TDS | 400 ppm Max. |
| 8 | Temperature | 30 Max. |
Electric power supply
| Voltage | 415 V ± 6% |
|---|---|
| Frequency | 50 HZ ± 3% |
| Phases | Three + Neutral |
| Earthing | Yes, double. |
Get a quotation for Nanomatic
Tell us the duty, the fuel available and your location. An engineer will call back with a selection and a price, usually within one working day.
- Office: +91 22 2859 0678
- Factory: +91 98210 28660
- sales@neotechboilers.com
You may also need

Minimatic
Mini Steam Boiler
Compact three-pass mini steam boiler with imported monoblock burners — ideal for replacing electrically heated steam boilers.

Neotherm E
Electrically Heated Thermic Fluid Heater
Skid-mounted electric thermic fluid heating system — 98 % efficient, 280 °C, no chimney, no fuel handling.

Revotech-G
Gas Fired Steam Boiler
Packaged non-IBR four-pass steam boiler with an imported, fully automatic gas burner — efficiency in the vicinity of 90 %.